Hioki 3280-10F AC CLAMP METER
$89.00
Product Features
Thin and strong clamp meter
Electric worker’s essential item! Voltage measurement is OK with this one!
AC Flexible Current Sensor CT6280 (Option) can be used! Easy measurement in complicated place
Expansion of operating temperature range due to expansion of operating temperature range
Basic specification (accuracy guarantee period 1 year, post-adjustment accuracy guarantee period 1 year),
product warranty period 3 years
【AC measurement method】 Mean value method (MEAN)
【Measurable conductor diameter】 φ 33 mm (Jaw thinness 9.5 mm)
[Maximum rated voltage between the ground] Clamp sensor: CAT IV 300 V, CAT III 600 V
___________ Voltage measurement terminal: CAT III 300 V, CAT II 600 V
【AC current】 42.00 A / 420.0 A / 1000 A (± 1.5% rdg. ± 5 dgt)
[Frequency band] 50/60 Hz
【AC voltage】 4.200 V ~ 600 V, 4 range (± 1.8% rdg. ± 7 dgt)
[Frequency band] 45 to 500 Hz
【DC voltage】 420.0 mV to 600 V, 5 ranges (± 1.0% rdg. ± 3 dgt)
[Resistance] 420.0 Ω to 42.00 MΩ, 6 ranges (± 2.0% rdg. ± 4 dgt)
【Continuity check】 420.0 Ω (± 2.0% rdg. ± 4 dgt)
[Display update rate] 400 ms
【Operating temperature and humidity range】 -25 ℃ ~ 85 ℃, 80% rh or less (noncondensing)
【Storage temperature and humidity range】 -25 ℃ ~ 65 ℃, 80% rh or less (noncondensing)
【Drop proof】 1 m above concrete
【Dustproof / Waterproof】 IP40
【Conformity standard】 Safety: EN 61010, EMC: EN 61326
[Function] Data hold, auto power save
【Power supply】 Coin type lithium battery CR2032x1
[Continuous use time] About 120 hours
【Dimensions · Weight】 57 W x 175 H x 16 D, 100 g
[Accessories] Portable case 9398, test lead L 9208, lithium battery CR 2032, instruction manual
There are no reviews yet.